• PRODUCTS

    Committed to becoming the most trusted partner of customers.

LC410 SERIES
Universal frequency converter, covering more than 90% applications
Perfect software and hardware protection function. The output frequency can reach to 500Hz, solved the traditional gear limit problem.
Contact us

Features

---Universal frequency converter, covering more than 90% applications

---Perfect software and hardware protection function. The output frequency can reach to 500Hz, solved the traditional gear limit problem.

---Powerful current vector control performance, low noise, excellent energy-saving effect 

---Speed tracking, Instantaneous stop, 0.1S acceleration and deceleration, 22G and below are with built-in brake unit 

---47 kinds of fault detection protection are set to effectively ensure the stable and reliable operation of the system.

---Extensive expansion card options 

---Powerful and supports multiple field buses            

---Support asynchronous motor control

--- Support user programmable control card (PLC card), and the programming method is fully compatible with H1U series PLC


Applications: numerical control machine, Forging Machine, textile machinery ,Roots Blower Lifting,  Plastic machinery , petroleum ,  Food machinery,etc.


Wiring Diagram

1.png


Technical Specification of LC410 Series


ItemTechnical IndexSpecification
InputInput voltage3AC 380~460V±15%
Input frequency50/60Hz±5%
OutputOutput voltage0~rated input voltage
Output frequencyV/f control: 0~2000Hz ;Vector control: 0~500Hz
Control FeaturesControl modeV/f control;Sensorless vector control (SVC);Close-loop vector control (FVC)
Operation command modeKeypad control/Terminal control/Serial communication control (Modbus)
Frequency setting modeDigital setting, analog setting, pulse frequency setting, serial communication setting, multi-step speed setting & simple PLC, PID setting, etc. These frequency settings can be combined & switched in various modes.
Overload capacityG model: 150%/60s, 180%/3s;P model: 120%/60s, 150%/3s
Starting torque0.25Hz/150% (SVC); 0.5Hz/150% (V/f), 0Hz/180% (FVC)
Speed control precision±0.5% (SVC)
Carrier frequency0.5~16.0kHz, automatically adjusted according to temperature and load characteristics
Frequency accuracyDigital setting: 0.01Hz;Analog setting: maximum frequency ×0.025%
Torque boostAutomatically torque boost; manually torque boost: 0.1%~30.0%
V/f curveThree types: linear, multiple point and square type (1.2 power, 1.4 power, 1.6 power, 1.8 power, square)
Acceleration/deceleration modeStraight line/S curve; four kinds of acceleration/deceleration time, range: 0.1s~6500.0s
Braking unit1.5~22kW: standard build-in.30~37kW optional for build-in;>37kW, external braking unit..
DC brakingDC braking when starting and stopping.DC braking frequency: 0.0Hz~maximum frequency, braking time: 0.0s~25.0s
Jog operationJog operation frequency: 0.0Hz~maximum frequency;Jog acceleration/deceleration time: 0.1s~6500.0s
Simple PLC & multi-step speed operationIt can realize a maximum of 16 multi-step speeds running via the built-in PLC or control terminal.
Built-in PIDBuilt-in PID control to easily realize the close loop control of the process parameters (such as pressure, temperature, flow, etc.)
Automatic voltage regulationKeep output voltage constant automatically when input voltage fluctuating
Control FunctionTorque limit“Rooter” characteristics, limit the torque automatically and prevent frequent over-current tripping during the running process
Wobble frequency controlMultiple triangular-wave frequency control, special for textile
Timing/length/counting controlTiming/length/counting control function
Over-voltage & over-current stall controlLimit current & voltage automatically during the running process, prevent frequent over-current & over-voltage tripping
Fault protection functionComprehensive protections include over-current, over-voltage, under-voltage, overheating, default phase, overload, shortcut, etc., can record the detailed running status during failure & has fault automatic reset function
Input/output terminalsInput terminalsProgrammable digital inputs: DI1~DI6, DI5 can be used as high speed pulse input terminal.Programmable analog inputs: AI1(0~10V), AI2(compile with both 0~10V & 4~20mA).
Output terminalsProgrammable digital outputs: 1 relay outputs (another 1 can be extended) 2 open-collector outputs, FM can be set as high speed pulse output terminal.Programmable analog outputs: AO1, AO2: compile with both 0~10V & 4~20mA.
Communication terminalsStandard RS485 communication interface, support MODBUS-RTU communication protocol
Human machine interfaceLED displayDisplay frequency setting, output frequency, output voltage, outputcurrent, etc. Two lines display
Multi-function keyMF.K key, can be used as multi-function key
Environ-mentAmbient temperature-10℃~40℃ (>40℃, output derated), without direct sunshine.
Humidity90%RH or less (non-condensing)
Altitude≤1000M: output rated power, >1000M: output derated
Storage temperature-20℃~60℃


Dimensions of LC410 Series

qq.jpg


Power(KW)A(mm)B(mm)H(mm)W(mm)D(mm) ID(mm)
Installation SizeOverall Size
1.5—41131721861251645
5.5—111482362481601835
15—221903053222081926
30—372354474632852286.5
45—752605806003852657
90—1323436787004733079
160—20044990393057938012.5
220—3154201030106065037712.5
355—4505201300136080038812.5
5007001130174083840512.5