--Single Phase AC 220V ±15% and three phase AC 380V±15% available. |
Input | Rated Voltageand Frequency | 3PH(4T Series)380V;50/60HZ 1PH(2T Series)220V:50/60HZ | |||
Allowable rangeOf voltage change | 3PH(4T Series)320V~460V 3PH(2T Series) 190V~250V | ||||
Output | Voltage | 4T series;0~380V 2T series;0~220V | |||
Frequency | 0~999.9HZ | ||||
Overload Capacity | 110% long time 150% 60s 180% 5s | ||||
Control Mode | V/F、Simple Vector Control、Advanced Vector Control、Torque Control | ||||
Control Characteristic | Resolution of Frequency | Anolog Input | 0.1% of Max output frequency | ||
Digital setting | 0.1HZ | ||||
Accuracy of Frequency | Anolog Input | 0.2% of Max output frequency | |||
Digital Input | 0.01% of Output frequency set | ||||
V/F Control | V/F Curve(Voltage frequency Characteristics) | Three ways: 1.the linear torque characteristic curve 2. the square torque characteristic curve 3. V / F curve set by the user | |||
Torque lift | Manual setting: 0.0~30.0% of the rated output Automatic lifting: the lifting torque is automatically determined according to the output current and the motor parameters | ||||
Automatic Limiting of current and pressure | During acceleration, deceleration or stable operation, the motor stator current and voltage are automatically detected under the unique algorithm to minimize the possibility of system fault trip | ||||
SVC | Voltage frequency Characteristics | The output pressure frequency ratio is automatically adjusted according to the motor parameters and the unique algorithm | |||
Torque Characteristics | starting torque: 100% Rated torque at 5.0Hz (VF control) 150% rated torque at 1.0Hz (vector control) | ||||
Current and voltage suppression | The whole current closed-loop control, completely avoid current impact, with perfect overflow pressure suppression function | ||||
Under voltage inhibition during operation | Especially for users with low grid voltage and frequent grid voltage fluctuations, the system can maintain the maximum possible operating time even within the allowable voltage range | ||||
Typical Function | Multi-Section speed operation | 7-segment programmable multi segment speed control, and multiple operation modes are optional | |||
PID ControlRS485 Communication | Built-in PID controller (pre-set frequency). Standard configuration of RS485 communication function, a variety of communication protocols are optional, with linkage synchronization control function | ||||
Frequency Set | Analog Input | DC voltage 0~10V, DC current 0 ~ 20 mA (upper and lower limits are optional | |||
Digital Input | Operation panel setting, RS485 interface setting, UP / DOWN terminal control, can also be combined with analog input | ||||
Output Signal | Relay Output | 1-way relay output (TA, TC), up to 17 choices | |||
Analog Output | 1 analog signal output, the output range is flexibly set between 0-20 mA or 0-10 V, which can realize the output of physical quantity such as set frequency and output frequency | ||||
Automatic Voltage Stabilization | According to the need, dynamic pressure, static pressure and unstable pressure can be selected to obtain the most stable operation effect | ||||
Acceleration and deceleration time setting | 0.1S~999.9min can be set continuously | ||||
Brake | Dynamic Braking | The energy braking starting voltage, return voltage and energy braking rate can be adjusted continuously | |||
DC injection braking | Start frequency of shutdown DC brake: 0.00~ [F0.05] upper limit frequency Brake time: 0.0~30.0s; Brake current: 0.0%~50.0% rated voltage of the motor | ||||
Low Noise operation | Carrier frequency 2.0KHZ~20.0KHZ is continuously adjustable to minimize motor noise | ||||
Counter | An internal counter for facilitate system integration | ||||
Running function | Upper and lower limit frequency setting, frequency jump operation, reverse operation limit, turn frequency compensation, RS485 communication, frequency increasing, decreasing control, fault self-recovery operation, etc |
Display | Operating panel display | Running Status | Output frequency, output current, output voltage, motor speed, set frequency, module temperature, PID setting, feedback amount, analog input and output, etc |
Alarm Content | Record the output frequency, set frequency, output current, output voltage, DC voltage, and module temperature of the latest fault | ||
Defensive Function | Over current, over voltage, under voltage, module fault, electronic thermal relay, overheating, short circuit, internal memory fault, etc | ||
Circumstance | Ambient Temperature | -10℃~+40℃((Ambient temperature is in 40℃ ~50℃, please decrease for use)) | |
Ambient Humidity | 5%~95%RH,no water beads condensation | ||
Ambient Environment | Indoor (no direct sunlight, no corrosion, flammable gas, no oil fog, dust, etc.) | ||
Altitude | Derate 10% for every 1000m increase | ||
structure | Protection Grade | IP20 | |
Cooling method | Air cooling, with fan control | ||
Installation method | Wall Mounting Type |